Radioactive Decay Lab: Half-Life with a Geiger-Müller Counter
Measure the background, count the random pulses of a decaying source interval by interval, plot the count rate with its √N error bars and take the half-life from the slope of ln(net rate) against time. Four school isotopes, a scaler, a stopwatch and a panel of nuclei that turn from parent to daughter.
Radioactive Decay: Half-Life, Counting Statistics and the Logarithmic Plot
A radioactive nucleus decays at a random moment, but a large sample follows a precise law: the number of undecayed nuclei falls as N = N₀e^(−λt) and halves every half-life T = ln 2 / λ. A Geiger-Müller counter registers only a fraction of the decays and adds a background of cosmic rays and natural radioactivity, so what you read in each interval is a random number that scatters by about the square root of itself.
This lab is the school half-life practical: a Geiger-Müller tube, a scaler, a stopwatch and a lead-shielded source store. You choose Ba-137m (2.552 min), Pa-234m (1.159 min), Rn-220 (55.6 s) or Ag-110 (24.6 s), measure the background, record the counts in each interval, subtract the background and plot ln(net rate) against time. The slope of the weighted straight-line fit is −λ, and the half-life comes with an uncertainty that you can compare with the accepted value. The counts are random but exactly reproducible: the same source number always gives the same data.
Frequently asked questions
What is a half-life?
The half-life is the time in which half of the radioactive nuclei in a large sample decay, or equivalently the time in which the activity halves. It is T = ln 2 / λ, where λ is the decay constant, and it does not depend on the size or the age of the sample: after two half-lives a quarter is left, after three an eighth.
Why do the counts change from one interval to the next?
Each nucleus decays at a random moment, so the number of decays in an interval is a Poisson random number. Its standard deviation is the square root of the mean: 1 600 counts carry an uncertainty of about 40 (2.5 %), while 100 counts carry 10 (10 %). That is why the error bars in the chart are √N.
Why must the background be subtracted?
A Geiger-Müller tube counts cosmic rays and natural radioactivity even with no source near it (here 0.4 counts per second). The background does not decay, so left in the data it bends the logarithmic graph away from a straight line and makes the half-life look too long. Count it for a long time with the source in its lead store, then subtract the rate from every interval.
How do you find the half-life from the graph?
Plot the natural logarithm of the net count rate against time. The rate is proportional to e^(−λt), so the points lie on a straight line of slope −λ, and T = ln 2 / λ. A weighted fit gives more influence to the intervals with a small relative uncertainty, and the error of the slope becomes the uncertainty of the half-life.