Enzyme Activity Lab: Catalase and Hydrogen Peroxide
Add liver extract to hydrogen peroxide in a water bath and collect the oxygen in an inverted measuring cylinder. Change the temperature, the pH of the buffer, the substrate concentration and the amount of enzyme, measure the rate of reaction and find where the enzyme works best and when it is denatured.
Enzymes: Catalase, Temperature, pH and the Rate of Reaction
An enzyme is a biological catalyst, a protein whose active site binds the substrate and lowers the activation energy of the reaction. Catalase, found in liver, potato and most living cells, splits hydrogen peroxide, a toxic by-product of metabolism, into water and oxygen: 2 H₂O₂ → 2 H₂O + O₂. The rate rises with temperature until the protein starts to unfold; heat then denatures the enzyme for good, and cooling it does not bring it back. The rate also depends on the pH, with a best value near neutral for liver catalase, and on the concentration of the substrate, where it levels off when every active site is busy.
This lab is the classic catalase practical. Hydrogen peroxide is in a boiling tube in a water bath, an extract is added with a syringe, and the oxygen is collected over water in an inverted measuring cylinder. Measure the volume in the first 5 seconds to get the initial rate, record it in a table and plot rate against temperature, pH and substrate concentration. A Lineweaver-Burk plot of 1/rate against 1/[substrate] gives the Michaelis constant Km and the maximum rate Vmax. The model uses Michaelis-Menten kinetics, an Arrhenius rise with temperature and a first-order, irreversible thermal denaturation.
Frequently Asked Questions
Why does the rate of an enzyme reaction fall at high temperature?
At first a higher temperature makes the molecules collide more often and with more energy, so the rate rises. Above the optimum the enzyme begins to unfold. The active site loses its shape, the substrate no longer fits and the enzyme is denatured. This is irreversible, so an extract that has been heated and cooled again does not recover its activity.
What is the optimum pH of catalase?
Liver catalase works best near neutral pH, around 7. In acid or alkaline solutions the charges on the amino acids in and near the active site change, the shape of the site is distorted and the rate falls. The curve is bell shaped, and in this model the enzyme is slowest at the ends of the range, pH 3 and pH 11.
Why does the rate stop rising when more hydrogen peroxide is added?
Each active site can only work on one substrate molecule at a time (catalase is a tetramer with four active sites). At a high substrate concentration all active sites are occupied and the rate reaches its maximum, Vmax; adding more substrate changes nothing, only more enzyme would. Km is the substrate concentration at which the rate is half of Vmax. Real catalase does not follow true Michaelis-Menten kinetics (two H₂O₂ are used per cycle, it hardly saturates and it is inactivated by high H₂O₂); its apparent Km values range from about 0.025 to above 1 mol/L, so at school concentrations the rate often keeps rising almost in proportion.
How can I tell if the enzyme is the limiting factor?
Double the amount of extract. The initial rate is proportional to the amount of enzyme at any temperature, pH and substrate concentration, so doubling the extract doubles the initial rate. The volume collected falls short of double only if the substrate runs out during the measurement or the cylinder fills up.
Why is the volume of oxygen limited to 100 cm³ here?
The inverted measuring cylinder holds 100 cm³. When more gas is produced than fits, the rest bubbles out of the cylinder and the reading stays at 100 cm³, so the rate seems to be smaller than it really is. Use less substrate or less extract, or read the volume after a shorter time.